Products

Zytel® HTN FR52G30BL BK337

Zytel® HTN FR52G30BL BK337

Manufacturer: DUPONT
Produced At:
 Import/ China
Product Category: PPA
Product No:
 Zytel HTN FR52G30BL BK337
Product Quantity: 25KG / BAG
Product Features:
 Flame Retardant

Zytel® HTN FR52G30BL BK337

HIGH PERFORMANCE POLYAMIDE RESIN
Product Description:
30% Glass Reinforced, Flame Retardant, PPA, High Performance Polyamide

Filler / Reinforcement 
  • Glass Fiber, 30% Filler by Weight

Additive 
  • Flame Retardant

Features 
  • Flame Retardant

RoHS Compliance 
  • Contact Manufacturer

Processing Method 
  • Injection Molding

Part Marking Code (ISO 11469)
  • PA6T/66-GF30FR(16+72)

Part Marking Code (SAE J1344)
  • >PPA-GF30FR<

Resin ID (ISO 1043)
  • PA6T/66-GF30FR(16+72)

Physical
Dry
Conditioned
Unit
Test Method
Density
1.62
--
g/cm³
ISO 1183
Molding Shrinkage



ISO 294-4
Across Flow
0.80
--
%

Flow
0.30
--
%

Mechanical
Dry
Conditioned
Unit
Test Method
Tensile Modulus
1.71E+6
--
psi
ISO 527-2
Tensile Stress (Break)
23200
--
psi
ISO 527-2
Tensile Strain (Break)
2.0
--
%
ISO 527-2
Flexural Modulus
1.45E+6
--
psi
ISO 178
Flexural Stress
34800
30500
psi
ISO 178
Poisson's Ratio
0.33
--

ISO 527
Impact
Dry
Conditioned
Unit
Test Method
Charpy Notched Impact Strength



ISO 179/1eA
-22°F
4.8
--
ft·lb/in²

73°F
4.8
--
ft·lb/in²

Charpy Unnotched Impact Strength



ISO 179/1eU
-22°F
19
17
ft·lb/in²

73°F
24
17
ft·lb/in²

Thermal
Dry
Conditioned
Unit
Test Method
Heat Deflection Temperature (264 psi, Unannealed)
540
--
°F
ISO 75-2/A
Melting Temperature 3
590
--
°F
ISO 11357-3
CLTE



ISO 11359-2
Flow
1.1E-5
--
in/in/°F

Flow : -40 to 73°F
1.1E-5
--
in/in/°F

Flow : 131 to 320°F
5.6E-6
--
in/in/°F

Transverse
3.5E-5
--
in/in/°F

Transverse : -40 to 73°F
3.2E-5
--
in/in/°F

Transverse : 131 to 320°F
5.6E-5
--
in/in/°F

Electrical
Dry
Conditioned
Unit
Test Method
Volume Resistivity
> 1.0E+15
--
ohms·cm
IEC 60093
Relative Permittivity



IEC 60250
100 Hz
3.50
--


1 MHz
3.30
--


Dissipation Factor



IEC 60250
100 Hz
5.0E-3
--


1 MHz
0.014
--


Flammability
Dry
Conditioned
Unit
Test Method
Flame Rating



UL 94, IEC 60695-11-10, -20
0.06 in
  • V-0

  • 5VA

--


0.12 in
V-0
--


Oxygen Index
42
--
%
ISO 4589-2
FMVSS Flammability
DNI
--

FMVSS 302
Fogging - F-value (refraction)
95
--
%
ISO 6452
Additional Information
Dry
Conditioned
Unit
Test Method
Emission of Organic Compounds
35.0
--
µgC/g
VDA 277
Odor
4.50
--

VDA 270
Injection
Dry
Unit

Drying Temperature
212
°F

Drying Time - Desiccant Dryer
6.0 to 8.0
hr

Suggested Max Moisture
0.10
%

Processing (Melt) Temp
608 to 626
°F

Melt Temperature, Optimum
617
°F

Mold Temperature
194 to 230
°F

Drying Recommended
yes




Products are widely used in plastic modification, automotive, construction, electrical and electronic, industrial, daily necessities and other fields


Consultation