Products

Zytel® MT409AHS BK010

Zytel® MT409AHS BK010

Manufacturer: DUPONT
Produced At:
 Import/ China
Product Category: PA66
Product No:
 Zytel MT409AHS BK010
Product Quantity: 25KG / BAG
Product Features:
 Heat Stabilized

Zytel® MT409AHS BK010

NYLON RESIN
Product Description:
Toughened, Heat Stabilized, Polyamide 66

Additive 
  • Heat Stabilizer

Features 
  • Heat Stabilized

RoHS Compliance 
  • Contact Manufacturer

Processing Method 
  • Injection Molding,Profile Extrusion 
Multi-Point Data 
  • Isothermal Stress vs. Strain (ISO 11403-1)

  • Secant Modulus vs. Strain (ISO 11403-1) 

Part Marking Code (ISO 11469)
  • PA66-I

Resin ID (ISO 1043)
  • PA66-I

Physical
Dry
Conditioned
Unit
Test Method
Density
1.11
--
g/cm³
ISO 1183
Molding Shrinkage



ISO 294-4
Across Flow
1.7
--
%

Flow
1.7
--
%

Water Absorption



ISO 62
73°F, 24 hr
0.90
--
%

Equilibrium, 73°F, 0.0787 in, 50% RH
2.1
--
%

Hardness
Dry
Conditioned
Unit
Test Method
Ball Indentation Hardness 3 (H 132/30)
18100
8700
psi
ISO 2039-1
Mechanical
Dry
Conditioned
Unit
Test Method
Tensile Modulus
348000
160000
psi
ISO 527-2
Tensile Stress (Yield)
8850
6240
psi
ISO 527-2
Tensile Strain (Yield)
5.0
28
%
ISO 527-2
Nominal Tensile Strain at Break
25
> 50
%
ISO 527-2
Flexural Modulus
319000
145000
psi
ISO 178
Flexural Stress
10900
--
psi
ISO 178
Poisson's Ratio
0.38
0.45

ISO 527
Impact
Dry
Conditioned
Unit
Test Method
Charpy Notched Impact Strength



ISO 179/1eA
-40°F
5.7
5.7
ft·lb/in²

-22°F
6.2
5.7
ft·lb/in²

73°F
9.0
19
ft·lb/in²

Charpy Unnotched Impact Strength



ISO 179/1eU
-22°F
No Break
No Break


73°F
No Break
No Break


Notched Izod Impact Strength



ISO 180/1A
-40°F
5.2
--
ft·lb/in²

-22°F
6.2
7.1
ft·lb/in²

73°F
8.1
43
ft·lb/in²

Thermal
Dry
Conditioned
Unit
Test Method
Heat Deflection Temperature




66 psi, Unannealed
369
--
°F
ISO 75-2/B
264 psi, Unannealed
149
--
°F
ISO 75-2/A
Melting Temperature 4
504
--
°F
ISO 11357-3
CLTE



ISO 11359-2
Flow
5.6E-5
--
in/in/°F

Transverse
5.6E-5
--
in/in/°F

Thermal Conductivity
1.5
--
Btu·in/hr/ft²/°F

Electrical
Dry
Conditioned
Unit
Test Method
Surface Resistivity
--
4.7E+11
ohms
IEC 60093
Volume Resistivity
> 1.0E+15
9.7E+11
ohms·cm
IEC 60093
Relative Permittivity



IEC 60250

Products are widely used in plastic modification, automotive, construction, electrical and electronic, industrial, daily necessities and other fields