Products

Zytel® FR7026V0F NC010

Zytel® FR7026V0F NC010

Manufacturer: DUPONT
Produced At:
 Import/ China
Product Category: PA66
Product No:
 Zytel FR7026V0F NC010
Product Quantity: 25KG / BAG
Product Features:
 Flame RetardantHalogen FreeHeat Stabilized

Zytel® FR7026V0F NC010

NYLON RESIN
Product Description:
Unreinforced, Flame Retardant, Non-Halogenated, Heat Stabilized, Polyamide 66

Additive 
  • Flame Retardant,Heat Stabilizer,Mold Release
Features 
  • Flame Retardant,Halogen Free,Heat Stabilized
RoHS Compliance 
  • Contact Manufacturer

Forms 
  • Pellets

Processing Method 
  • Injection Molding

Multi-Point Data 
  • Isothermal Stress vs. Strain (ISO 11403-1)

  • Secant Modulus vs. Strain (ISO 11403-1) 

Part Marking Code (ISO 11469)
  • PA66-FR(30)

Resin ID (ISO 1043)
  • PA66-FR(30)

Physical
Dry
Conditioned
Unit
Test Method
Density
1.16
--
g/cm³
ISO 1183
Molding Shrinkage



ISO 294-4
Across Flow
1.0
--
%

Flow
0.90
--
%

Water Absorption



ISO 62
Saturation, 73°F, 0.0787 in
8.0
--
%

Equilibrium, 73°F, 0.0787 in, 50% RH
2.4
--
%

Viscosity Number
160
--
cm³/g
ISO 307
Hardness
Dry
Conditioned
Unit
Test Method
Ball Indentation Hardness 3 (H 358/30)
--
16000
psi
ISO 2039-1
Mechanical
Dry
Conditioned
Unit
Test Method
Tensile Modulus
551000
261000
psi
ISO 527-2
Tensile Stress



ISO 527-2
Yield
--
8700
psi

Break
11600
--
psi

Tensile Strain



ISO 527-2
Yield
--
21
%

Break
10
--
%

Nominal Tensile Strain at Break
--
30
%
ISO 527-2
Poisson's Ratio
0.36
0.41

ISO 527
Impact
Dry
Conditioned
Unit
Test Method
Charpy Notched Impact Strength



ISO 179/1eA
-22°F
1.4
0.95
ft·lb/in²

73°F
1.7
3.3
ft·lb/in²

Charpy Unnotched Impact Strength(73°F)
38
52
ft·lb/in²
ISO 179/1eU
Notched Izod Impact Strength(73°F)
2.1
--
ft·lb/in²
ISO 180/1A
Thermal
Dry
Conditioned
Unit
Test Method
Heat Deflection Temperature




66 psi, Unannealed
446
--
°F
ISO 75-2/B
264 psi, Unannealed
176
--
°F
ISO 75-2/A
Melting Temperature 4
500
--
°F
ISO 11357-3
Electrical
Dry
Conditioned
Unit
Test Method
Surface Resistivity 5
--
> 1.0E+15
ohms
IEC 60093
Electric Strength
790
--
V/mil
IEC 60243-1
Comparative Tracking Index (CTI)
PLC 0
--

UL 746
Comparative Tracking Index
600
--
V
IEC 60112
Flammability
Dry
Conditioned
Unit
Test Method
Flame Rating



UL 94, IEC 60695-11-10, -20
0.03 in
V-0
--


0.06 in
V-0
--


Glow Wire Flammability Index



IEC 60695-2-12
0.016 in
1760
--
°F

0.030 in
1760
--
°F

0.06 in
1760
--
°F

0.12 in
1760
--
°F

Glow Wire Ignition Temperature



IEC 60695-2-13
0.016 in
1760
--
°F

0.030 in
1760
--
°F

0.06 in
1760
--
°F

0.12 in
1760
--
°F

Oxygen Index
39
--
%
ISO 4589-2
FMVSS Flammability
DNI
--

FMVSS 302
Fill Analysis
Dry
Conditioned
Unit
Test Method
Melt Density
1.03
--
g/cm³

Ejection Temperature
410
--
°F

Specific Heat Capacity of Melt
0.619
--
Btu/lb/°F

Thermal Conductivity of Melt
1.2
--
Btu·in/hr/ft²/°F

Additional Information
Dry
Conditioned
Unit
Test Method
Odor
5.00
--

VDA 270
Injection
Dry
Unit

Drying Temperature
176
°F

Drying Time - Desiccant Dryer
2.0 to 4.0
hr

Suggested Max Moisture
0.20
%

Processing (Melt) Temp
518 to 554
°F

Melt Temperature, Optimum
536
°F

Mold Temperature
122 to 194
°F

Mold Temperature, Optimum
158
°F

Holding Pressure
7250 to 14500
psi

Drying Recommended
yes


Hold Pressure Time
3.00
s/mm

Maximum Screw Tangential Speed
472

Products are widely used in plastic modification, automotive, construction, electrical and electronic, industrial, daily necessities and other fields