Product Features:
 Chemical ResistantCreep ResistantFast Molding CycleGood Dimensional StabilityGood StiffnessHeat StabilizedHigh Heat ResistanceHigh StrengthHot Water MoldabilityLaser WeldableLow Moisture AbsorptionLubricated

Amodel® AS-4133 HS

Polyphthalamide
Product Description:
Amodel® AS-4133 HS is a 33% glass reinforced, lubricated, heat stabilized grade of polyphthalamide (PPA) that offers fast cycle times and moldability in hot water molds. Testing conducted on samples dry as molded and samples conditioned to 50% relative humidity in accordance with ISO-1110, Accelerated Method. Typical applications include electrical and electronic components especially for automotive systems.

  • Black: AS-4133 HS BK 324

  • Natural: AS-4133 HS NT


Filler / Reinforcement 
  • Glass Fiber, 33% Filler by Weight

Additive 
  • Heat Stabilizer,Lubricant,Mold Release
Features 
  • Chemical Resistant,Creep Resistant,Fast Molding Cycle,

  • Good Dimensional Stability,Good Stiffness,Heat Stabilized,High Heat Resistance,

  • High Strength,Hot Water Moldability,Laser Weldable,Low Moisture Absorption,Lubricated

Uses 
  • Automotive Applications,Automotive Electronics,Automotive Under the Hood,Cell Phones,Connectors,Electrical/Electronic Applications,General Purpose,Industrial Applications,Industrial Parts,Lawn and Garden Equipment,Machine/Mechanical Parts,

  • Metal Replacement,Thick-walled Parts,Valves/Valve Parts

RoHS Compliance 
  • RoHS Compliant

Appearance 
  • Black,Natural Color 
Forms 
  • Pellets

Processing Method 
  • Water-Heated Mold Injection Molding

Multi-Point Data 
  • Isothermal Stress vs. Strain (ISO 11403-1)

  • Secant Modulus vs. Strain (ISO 11403-1)

  • Viscosity vs. Shear Rate (ISO 11403-2)

Physical
Dry
Conditioned
Unit
Test Method
Density
1.45
--
g/cm³
ISO 1183/A
Molding Shrinkage



ASTM D955
Flow
5.0E-3
--
in/in

Across Flow
0.010
--
in/in

Water Absorption (24 hr)
0.29
--
%
ASTM D570
Mechanical
Dry
Conditioned
Unit
Test Method
Tensile Modulus




--
1.70E+6
1.70E+6
psi
ASTM D638
73°F
1.83E+6
--
psi
ISO 527-2
212°F
990000
--
psi
ISO 527-2
302°F
770000
--
psi
ISO 527-2
347°F
700000
--
psi
ISO 527-2
Tensile Stress




Break, 73°F
30600
--
psi
ISO 527-2
Break, 212°F
18100
--
psi
ISO 527-2
Break, 302°F
12700
--
psi
ISO 527-2
Break, 347°F
11500
--
psi
ISO 527-2
--
29000
25000
psi
ASTM D638
Tensile Elongation




Break
2.5
2.2
%
ASTM D638
Break, 73°F
2.6
--
%
ISO 527-2
Break, 212°F
4.3
--
%
ISO 527-2
Break, 302°F
6.6
--
%
ISO 527-2
Break, 347°F
6.6
--
%
ISO 527-2
Flexural Modulus




--
1.60E+6
1.60E+6
psi
ASTM D790
73°F
1.51E+6
--
psi
ISO 178
212°F
1.04E+6
--
psi
ISO 178
302°F
670000
--
psi
ISO 178
347°F
610000
--
psi
ISO 178
Flexural Strength




--
42000
35000
psi
ASTM D790
73°F
42900
--
psi
ISO 178
212°F
25600
--
psi
ISO 178
302°F
16100
--
psi
ISO 178
347°F
14400
--
psi
ISO 178
Compressive Strength
26000
25000
psi
ASTM D695
Shear Strength
13000
11000
psi
ASTM D732
Poisson's Ratio
0.41
--

ASTM E132
Impact
Dry
Conditioned
Unit
Test Method
Charpy Notched Impact Strength(73°F)
5.1
--
ft·lb/in²
ISO 179/1eA
Charpy Unnotched Impact Strength(73°F)
32
--
ft·lb/in²
ISO 179/1eU
Notched Izod Impact




--
1.5
1.3
ft·lb/in
ASTM D256
73°F
4.6
--
ft·lb/in²
ISO 180/1A
Unnotched Izod Impact




--
18
--
ft·lb/in
ASTM D256
73°F
28
--
ft·lb/in²
ISO 180/1U
Thermal
Dry
Conditioned
Unit
Test Method
Deflection Temperature Under Load




66 psi, Annealed, 0.126 in
608
--
°F
ASTM D648
264 psi, Unannealed
561
--
°F
ISO 75-2/A
264 psi, Annealed, 0.126 in
572
--
°F
ASTM D648
Continuous Use Temperature 3
410
--
°F
ASTM D3045
Melting Temperature
608
--
°F
ASTM D3418, ISO 11357-3
CLTE



ASTM E831
Flow : 32 to 212°F
1.1E-5
--
in/in/°F

Flow : 212 to 392°F
8.1E-6
--
in/in/°F

Transverse : 32 to 212°F
4.2E-5
--
in/in/°F

Transverse : 212 to 392°F
6.7E-5
--
in/in/°F

Electrical
Dry
Conditioned
Unit
Test Method
Volume Resistivity
2.0E+16
5.0E+14
ohms·cm
ASTM D257
Dielectric Strength (0.0630 in)
510
520
V/mil
ASTM D149
Dielectric Constant



ASTM D150
60 Hz
3.80
4.30


1 MHz
3.60
3.40


Dissipation Factor



ASTM D150
60 Hz
4.0E-3
0.020


1 MHz
0.012
0.019


Comparative Tracking Index (CTI)
600
600
V
UL 746
High Voltage Arc Tracking Rate (HVTR)
0.551
0.709
in/min
UL 746
Flammability
Dry
Conditioned
Unit
Test Method

Products are widely used in plastic modification, automotive, construction, electrical and electronic, industrial, daily necessities and other fields