Products

Amilan® CM3004G-30

Amilan® CM3004G-30

Manufacturer:  TORAY
Produced At:
  Japan / China
Product Category:  PA66
Product No:  Amilan CM3004G-30
Product Quantity:  25KG / BAG
Product Features: Flame Retardant
Halogen Free

Amilan® CM3004G-30

Polyamide 66
Product Description:
Amilan® CM3004G-30 is a Polyamide 66 (Nylon 66) product filled with 30% glass fiber. It is available in Asia Pacific, Europe, or North America. Applications of Amilan® CM3004G-30 include appliances, automotive, business/office goods, electrical/electronic applications and housings.

Characteristics include:
  • Flame Rated

  • Flame Retardant


Filler / Reinforcement 
  • Glass Fiber, 30% Filler by Weight

Additive 
  • Flame Retardant

Features 
  • Flame Retardant,Halogenated 
Uses 
  • Appliances,Automotive Applications,Electrical Parts,Housings,Office Automation Equipment
Part Marking Code 
  • >PA66-GF30FR<

Physical
Dry
Conditioned
Unit
Test Method
Density (73°F)
1.59
--
g/cm³
ISO 1183
Molding Shrinkage 3



Internal Method
Across Flow : 0.118 in
0.60 to 0.90
--
%

Flow : 0.118 in
0.20 to 0.50
--
%

Water Absorption



ISO 62
73°F, 24 hr
0.60
--
%

Saturation, 73°F
4.0
--
%

Hardness
Dry
Conditioned
Unit
Test Method
Rockwell Hardness (R-Scale, 73°F)
121
--

ISO 2039-2
Mechanical
Dry
Conditioned
Unit
Test Method
Tensile Stress



ISO 527-2
-40°F
27600
--
psi

73°F
23900
19600
psi

176°F
16000
--
psi

Tensile Strain



ISO 527-2
Break, -40°F
2.5
--
%

Break, 73°F
3.0
3.0
%

Break, 176°F
4.5
--
%

Flexural Modulus



ISO 178
-40°F
1.48E+6
--
psi

73°F
1.35E+6
943000
psi

176°F
798000
--
psi

Flexural Stress



ISO 178
-40°F
39900
--
psi

73°F
36300
29000
psi

176°F
21800
--
psi

Taber Abrasion Resistance (1000 Cycles)
26.0
--
mg
ISO 9352
Impact
Dry
Conditioned
Unit
Test Method
Charpy Notched Impact Strength



ISO 179
-40°F
3.3
--
ft·lb/in²

73°F
4.5
6.7
ft·lb/in²

Charpy Unnotched Impact Strength(73°F)
31
33
ft·lb/in²
ISO 179
Thermal
Dry
Conditioned
Unit
Test Method
Heat Deflection Temperature (66 psi, Unannealed)
484
--
°F
ISO 75-2/B
Melting Temperature
509
--
°F
DSC
CLTE - Flow
1.1E-5
--
in/in/°F
ISO 11359-2
Electrical
Dry
Conditioned
Unit
Test Method
Volume Resistivity
1.0E+13
1.0E+11
ohms·cm
IEC 60093
Electric Strength
970
840
V/mil
IEC 60243-1
Dielectric Constant 4



IEC 60250
73°F, 1 kHz
4.00
--


73°F, 1 MHz
0.0100
--


Arc Resistance 5
70.0
--
sec
UL 746
Comparative Tracking Index (CTI)
200
--
V
UL 746
Flammability
Dry
Conditioned
Unit
Test Method
Flame Rating (0.016 in)
V-0
V-0

UL 94


Products are widely used in plastic modification, automotive, construction, electrical and electronic, industrial, daily necessities and other fields


Consultation
展开