Products

Amilan® CM3001G-45

Amilan® CM3001G-45

Manufacturer:  TORAY
Produced At:
  Japan / China
Product Category:  PA66
Product No:  Amilan CM3001G-45
Product Quantity:  25KG / BAG
Product Features: flame rated

Amilan® CM3001G-45

Polyamide 66
Product Description:
Amilan® CM3001G-45 is a Polyamide 66 (Nylon 66) product filled with 45% glass fiber. It is available in Asia Pacific, Europe, or North America. Applications of Amilan® CM3001G-45 include appliances, automotive, electrical/electronic applications and housings. Primary characteristic: flame rated.

Filler / Reinforcement 
  • Glass Fiber, 45% Filler by Weight

Uses 
  • Appliances,Automotive Applications,Electrical/Electronic Applications,Housings 
Part Marking Code 
  • >PA66-GF30<

Physical
Dry
Conditioned
Unit
Test Method
Density (73°F)
1.50
--
g/cm³
ISO 1183
Molding Shrinkage 3



Internal Method
Across Flow : 0.118 in
0.50 to 0.80
--
%

Flow : 0.118 in
0.20 to 0.40
--
%

Water Absorption



ISO 62
73°F, 24 hr
0.40
--
%

Saturation, 73°F
4.8
--
%

Hardness
Dry
Conditioned
Unit
Test Method
Rockwell Hardness



ISO 2039-2
M-Scale, 73°F
103
--


R-Scale, 73°F
121
--


Mechanical
Dry
Conditioned
Unit
Test Method
Tensile Stress



ISO 527-2
-40°F
40600
36300
psi

73°F
31900
23900
psi

176°F
20300
16700
psi

Tensile Strain



ISO 527-2
Break, -40°F
2.5
--
%

Break, 73°F
3.0
--
%

Break, 176°F
5.5
--
%

Flexural Modulus



ISO 178
-40°F
2.25E+6
2.09E+6
psi

73°F
2.00E+6
1.60E+6
psi

176°F
1.25E+6
1.06E+6
psi

Flexural Stress



ISO 178
-40°F
55100
50800
psi

73°F
50000
42800
psi

176°F
33400
28300
psi

Compressive Stress



ISO 604
-40°F
38400
--
psi

73°F
28300
--
psi

176°F
17400
--
psi

Shear Strength (73°F)
15200
--
psi
ASTM D732
Impact
Dry
Conditioned
Unit
Test Method
Charpy Notched Impact Strength



ISO 179
-40°F
5.5
5.7
ft·lb/in²

73°F
7.1
7.9
ft·lb/in²

Charpy Unnotched Impact Strength



ISO 179
-40°F
40
43
ft·lb/in²

73°F
43
48
ft·lb/in²

Thermal
Dry
Conditioned
Unit
Test Method
Heat Deflection Temperature (66 psi, Unannealed)
505
--
°F
ISO 75-2/B
Melting Temperature
509
--
°F
DSC
CLTE - Flow
1.1E-5 to 1.7E-5
--
in/in/°F
ISO 11359-2
Specific Heat
0.359
--
Btu/lb/°F

Thermal Conductivity
2.9
--
Btu·in/hr/ft²/°F

Electrical
Dry
Conditioned
Unit
Test Method
Volume Resistivity
1.0E+13
1.0E+10 to 1.0E+11
ohms·cm
IEC 60093
Electric Strength
480
--
V/mil
IEC 60243-1
Dielectric Constant 4



IEC 60250
73°F, 50 Hz
4.70
--


73°F, 1 kHz
4.50
--


73°F, 1 MHz
4.10
--


Dissipation Factor 4



IEC 60250
73°F, 50 Hz
0.020
--


73°F, 1 kHz
0.020
--


73°F, 1 MHz
0.020
--


Flammability
Dry
Conditioned
Unit
Test Method
Flame Rating (0.031 in)
HB
HB

UL 94


Products are widely used in plastic modification, automotive, construction, electrical and electronic, industrial, daily necessities and other fields


Consultation
展开