Products

ForTii® K12

ForTii® K12

Manufacturer: DSM
Produced At:
 Europe / China
Product Category: Polyamide 4T
PA4T
Product No: ForTii K12   
Product Quantity: 25KG / BAG
Product Features: Lubricated 

ForTii® K12

Polyamide 4T
Product Description:
40% Glass Reinforced, for E&E applications

Special Features:
  • Contains release agent

  • Lubricated


Used In:
  • Reflow connectors (3)


ForTii® is a breakthrough high temperature polyamide with halogen-free flame retardant grades for demanding applications in the electronics, lighting, automotive, white goods, industrial and aerospace industries.
We developed ForTii® in close co-operation with leading OEMs and tier 1 connector and socket manufacturers to ensure we give our customer what they want €" and need.
That means a high temperature polyamide with a broad and versatile portfolio of grades that deliver high performance with a unique balance of properties.

Filler / Reinforcement 
  • Glass Fiber, 40% Filler by Weight

Additive 
  • Lubricant,Mold Release 
Features 
  • Lubricated

Uses 
  • Connectors

Processing Method 
  • Injection Molding

Resin ID (ISO 1043)
  • PA4T-GF40

Physical
Dry
Conditioned
Unit
Test Method
Density
1.53
--
g/cm³
ISO 1183
Water Absorption



ISO 62
Saturation, 73°F
4.8
--
%

Equilibrium, 73°F, 50% RH
1.8
--
%

Mechanical
Dry
Conditioned
Unit
Test Method
Tensile Modulus
1.96E+6
--
psi
ISO 527-2
Tensile Stress (Break)
30500
--
psi
ISO 527-2
Tensile Strain (Break)
2.0
--
%
ISO 527-2
Flexural Modulus
1.96E+6
--
psi
ISO 178
Flexural Stress
47900
--
psi
ISO 178
Impact
Dry
Conditioned
Unit
Test Method
Charpy Notched Impact Strength(73°F)
5.2
--
ft·lb/in²
ISO 179/1eA
Charpy Unnotched Impact Strength(73°F)
31
--
ft·lb/in²
ISO 179/1eU
Thermal
Dry
Conditioned
Unit
Test Method
Heat Deflection Temperature




66 psi, Unannealed
608
--
°F
ISO 75-2/B
264 psi, Unannealed
581
--
°F
ISO 75-2/A
Glass Transition Temperature 3
257
--
°F
ISO 11357-2
Melting Temperature 3
617
--
°F
ISO 11357-3
CLTE



ASTM D696
Flow
1.7E-5
--
in/in/°F

Transverse
2.2E-5
--
in/in/°F

Electrical
Dry
Conditioned
Unit
Test Method
Volume Resistivity
> 1.0E+15
> 1.0E+15
ohms·cm
IEC 60093
Electric Strength
840
840
V/mil
IEC 60243-1
Relative Permittivity



IEC 60250
100 Hz
5.00
5.00


1 MHz
4.50
4.50


Dissipation Factor



IEC 60250
100 Hz
0.012
0.012


1 MHz
0.025
0.025


Comparative Tracking Index
600
--
V
IEC 60112
Flammability
Dry
Conditioned
Unit
Test Method
Flammability Classification



IEC 60695-11-10, -20
0.03 in
HB
--


0.06 in
HB
--


Injection
Dry
Unit

Drying Temperature
212
°F

Drying Time
4.0 to 8.0
hr

Rear Temperature
608 to 626
°F

Middle Temperature
617 to 635
°F

Front Temperature
626 to 635
°F

Nozzle Temperature
626 to 635
°F

Processing (Melt) Temp
626 to 644
°F

Mold Temperature
212 to 302
°F

Injection Rate
Moderate-Fast


Back Pressure
72.5 to 435
psi

Screw Compression Ratio
2.5:1.0




Products are widely used in plastic modification, automotive, construction, electrical and electronic, industrial, daily necessities and other fields


Consultation
展开