Radiflam® A RV350 AF 333 NER

Radiflam® A RV350 AF 333 NER

Manufacturer: RADICI
Produced At:
 Europe / China
Product Category: Polyamide 66 (Nylon 66)
Product No: Radiflam A RV350 AF 333 NER 
Product Quantity: 25KG / BAG
Product Features: Flame Retardant,High Stiffness

Radiflam® A RV350 AF 333 NER

Polyamide 66
Product Description:

PA66 flame retardant injection moulding grade with red phosphorus. 35% glass fiber reinforced. Black colour.

Suitable for parts requiring fire retardancy along with high stiffness and good mechanical resistance.
Rated V-0 at 0.75 mm according to UL-94.

ISO 1043 : PA66 GF35 FR(52+72)


Filler / Reinforcement 
  • Glass Fiber, 35% Filler by Weight

Additive 
  • Flame Retardant

Features 
  • Flame Retardant,High Stiffness 
RoHS Compliance 
  • RoHS Compliant

UL File Number 
  • E116324

Appearance 
  • Black

Processing Method 
  • Injection Molding

Resin ID (ISO 1043)
  • PA66 GF35 FR(52+72)

Physical
Dry
Conditioned
Unit
Test Method
Density
1.48
--
g/cm³
ISO 1183
Water Absorption



ISO 62
Saturation, 73°F, 0.0787 in
5.4
--
%

Equilibrium, 73°F, 0.0787 in, 50% RH
1.3
--
%

Mechanical
Dry
Conditioned
Unit
Test Method
Tensile Modulus
1.64E+6
1.32E+6
psi
ISO 527-2/1A/1
Tensile Stress (Break)
22500
14500
psi
ISO 527-2/1A/5
Tensile Strain (Break)
2.7
3.0
%
ISO 527-2/1A/5
Flexural Modulus 3
1.49E+6
--
psi
ISO 178
Flexural Stress 3
33400
--
psi
ISO 178
Impact
Dry
Conditioned
Unit
Test Method
Charpy Notched Impact Strength



ISO 179/1eA
-22°F
4.3
--
ft·lb/in²

73°F
5.7
6.2
ft·lb/in²

Charpy Unnotched Impact Strength



ISO 179/1eU
-22°F
26
--
ft·lb/in²

73°F
31
33
ft·lb/in²

Thermal
Dry
Conditioned
Unit
Test Method
Heat Deflection Temperature




66 psi, Unannealed
482
--
°F
ISO 75-2/Bf
264 psi, Unannealed
455
--
°F
ISO 75-2/Af
Vicat Softening Temperature
473
--
°F
ISO 306/B50
Melting Temperature 4
500
--
°F
ISO 11357
Electrical
Dry
Conditioned
Unit
Test Method
Surface Resistivity
1.0E+12
1.0E+10
ohms
IEC 60093
Volume Resistivity
1.0E+15
1.0E+13
ohms·cm
IEC 60093
Comparative Tracking Index
500
--
V
IEC 60112
Flammability
Dry
Conditioned
Unit
Test Method
Burning Rate
0.0
--
in/min
FMVSS 302
Flame Rating (0.031 in)
V-0
--

UL 94
Glow Wire Flammability Index



IEC 60695-2-12
0.04 in
1760
--
°F

0.08 in
1760
--
°F

Glow Wire Ignition Temperature



IEC 60695-2-13
0.04 in
1340
--
°F

0.08 in
1380
--
°F

Injection
Dry
Unit

Drying Temperature - Desiccant Dryer
176
°F

Drying Time - Desiccant Dryer
2.0 to 4.0
hr

Dew Point - Desiccant Dryer
< -4
°F

Suggested Max Moisture
0.10
%

Processing (Melt) Temp
536 to 572
°F

Mold Temperature
176 to 212
°F

Injection Rate
Moderate-Fast




Products are widely used in plastic modification, automotive, construction, electrical and electronic, industrial, daily necessities and other fields