Products

Radiflam® A RV250 HF 333 NER 4244

Radiflam® A RV250 HF 333 NER 4244

Manufacturer: RADICI
Produced At:
 Europe / China
Product Category: Polyamide 66 (Nylon 66)
Product No: Radiflam A RV250 HF 333 NER 4244 
Product Quantity: 25KG / BAG
Product Features: Electrically Insulating,Flame Retardant,Good Electrical Properties,Medium Stiffness

Radiflam® A RV250 HF 333 NER 4244

Polyamide 66
Product Description:

PA66 flame retardant for injection molding, halogens and red phosphorus. reinforced with 25% glass fiber. Black Colour.
Suitable for parts requiring properties to flame retardants, medium stiffness and good resistance mechanics. Good electrical insulation properties. Ranked V-0 according to UL-94.


Filler / Reinforcement 
  • Glass Fiber, 25% Filler by Weight

Additive 
  • Flame Retardant

Features 
  • Electrically Insulating,Flame Retardant,Good Electrical Properties,

  • Medium Stiffness

RoHS Compliance 
  • RoHS Compliant

Appearance 
  • Black

Processing Method 
  • Injection Molding

Resin ID (ISO 1043)
  • PA66 GF25 FR(40+72)

Physical
Dry
Conditioned
Unit
Test Method
Density
1.36
--
g/cm³
ISO 1183
Water Absorption



ISO 62
Saturation, 73°F, 0.0787 in
5.5
--
%

Equilibrium, 73°F, 0.0787 in, 50% RH
1.3
--
%

Mechanical
Dry
Conditioned
Unit
Test Method
Tensile Modulus
1.41E+6
--
psi
ISO 527-2/1A/1
Tensile Stress (Break)
21000
--
psi
ISO 527-2/1A/5
Tensile Strain (Break)
2.7
--
%
ISO 527-2/1A/5
Flexural Modulus 3
1.35E+6
--
psi
ISO 178
Flexural Stress 3
31200
--
psi
ISO 178
Impact
Dry
Conditioned
Unit
Test Method
Charpy Notched Impact Strength(73°F)
4.8
--
ft·lb/in²
ISO 179/1eA
Charpy Unnotched Impact Strength(73°F)
29
--
ft·lb/in²
ISO 179/1eU
Thermal
Dry
Conditioned
Unit
Test Method
Heat Deflection Temperature (264 psi, Unannealed)
464
--
°F
ISO 75-2/Af
Vicat Softening Temperature
473
--
°F
ISO 306/B50
Melting Temperature 4
500
--
°F
ISO 11357-3
Electrical
Dry
Conditioned
Unit
Test Method
Surface Resistivity 5
1.0E+12
1.0E+10
ohms
IEC 60093
Volume Resistivity 5
1.0E+15
1.0E+13
ohms·cm
IEC 60093
Comparative Tracking Index(Solution A)
550
--
V
IEC 60112
Flammability
Dry
Conditioned
Unit
Test Method
Flame Rating (0.031 in)
V-0
--

UL 94
Glow Wire Flammability Index



IEC 60695-2-12
0.04 in
1760
--
°F

0.08 in
1760
--
°F

Glow Wire Ignition Temperature



IEC 60695-2-13
0.04 in
1340
--
°F

0.08 in
1430
--
°F

Flammability
0
--
in/min
FMVSS 302
Injection
Dry
Unit

Drying Temperature - Desiccant Dryer
176
°F

Drying Time - Desiccant Dryer
2.0 to 4.0
hr

Dew Point - Desiccant Dryer
< -4
°F

Suggested Max Moisture
0.10
%

Processing (Melt) Temp
536 to 572
°F

Mold Temperature
176 to 212
°F

Injection Rate
Moderate-Fast




Products are widely used in plastic modification, automotive, construction, electrical and electronic, industrial, daily necessities and other fields