Products

Torelina® A504FG1

Torelina® A504FG1

Manufacturer:  TORAY
Produced At:
  Japan / China
Product Category:  PPS
Product No:  Torelina A504FG1
Product Quantity:  25KG / BAG

Product Features:  High Flow


Torelina® A504FG1

Polyphenylene Sulfide
Product Description:
Torelina® A504FG1 is a Polyphenylene Sulfide (PPS) product filled with 40% glass fiber. It is available in Asia Pacific, Europe, or North America. Typical application: Electrical/Electronic Applications.

Characteristics include:
  • Flame Rated

  • High Flow


Filler / Reinforcement 
  • Glass Fiber, 40% Filler by Weight

Features 
  • High Flow

Uses 
  • Electrical Parts

Appearance 
  • Black,Natural Color 
Part Marking Code 
  • >PPS-GF40<

Physical
Nominal Value
Unit
Test Method
Density (73°F)
1.66
g/cm³
ISO 1183
Molding Shrinkage 3


Internal Method
Across Flow : 0.118 in
0.80
%

Flow : 0.118 in
0.20
%

Water Absorption (73°F, 24 hr)
0.020
%
ISO 62
Hardness
Nominal Value
Unit
Test Method
Rockwell Hardness (R-Scale)
123

ISO 2039-2
Mechanical
Nominal Value
Unit
Test Method
Tensile Stress (73°F)
23900
psi
ISO 527-2
Tensile Strain (Break, 73°F)
1.4
%
ISO 527-2
Flexural Modulus (73°F)
2.25E+6
psi
ISO 178
Flexural Stress (73°F)
36300
psi
ISO 178
Shear Strength (73°F)
10900
psi
JIS K7214
Coefficient of Friction 4
0.25


Taber Abrasion Resistance (1000 Cycles)
50.0
mg
ISO 9352
Impact
Nominal Value
Unit
Test Method
Charpy Notched Impact Strength (73°F)
4.8
ft·lb/in²
ISO 179
Charpy Unnotched Impact Strength (73°F)
14
ft·lb/in²
ISO 179
Thermal
Nominal Value
Unit
Test Method
Heat Deflection Temperature (264 psi, Unannealed)
500
°F
ISO 75-2/A
Melting Temperature
532
°F
ISO 11357-3
CLTE


ISO 11359-2
Flow
1.3E-5
in/in/°F

Transverse
1.7E-5
in/in/°F

Electrical
Nominal Value
Unit
Test Method
Volume Resistivity
1.0E+14
ohms·cm
IEC 60093
Electric Strength
560
V/mil
IEC 60243-1
Dielectric Constant 5 (73°F, 1 MHz)
3.60

IEC 60250
Dissipation Factor 5 (73°F, 1 MHz)
2.0E-3

IEC 60250
Flammability
Nominal Value
Unit
Test Method
Flame Rating (0.011 in)
V-0

UL 94
Additional Information
Nominal Value
Unit
Test Method
Bar Flow Length 6 (608°F, 39.4 mil)
7.9
in
Internal Method


Products are widely used in plastic modification, automotive, construction, electrical and electronic, industrial, daily necessities and other fields


Consultation
展开