Products

Radilon® A CP300K 333 NER

Radilon® A CP300K 333 NER

Manufacturer: RADICI
Produced At:
 Europe / China
Product Category: Polyamide 66 (Nylon 66)
Product No: Radilon A CP300K 333 NER 
Product Quantity: 25KG / BAG
Product Features: 
Good Dimensional Stability,Heat Stabilized,Low Shrinkage

Radilon® A CP300K 333 NER

Polyamide 66
Product Description:

PA66 30% mineral filled injection moulding grade. Heat stabilized. Black colour.

Suitable for parts requiring good dimensional stability, reduced shrinkage and low warpage.

ISO 1043 : PA66-T MX30


Filler / Reinforcement 
  • Mineral, 30% Filler by Weight

Additive 
  • Heat Stabilizer

Features 
  • Good Dimensional Stability,Heat Stabilized,Low Shrinkage
RoHS Compliance 
  • RoHS Compliant

Appearance 
  • Black

Processing Method 
  • Injection Molding

Resin ID (ISO 1043)
  • PA66-T MX30

Physical
Dry
Conditioned
Unit
Test Method
Density
1.36
--
g/cm³
ISO 1183
Molding Shrinkage 2



ISO 294-4
Across Flow
1.5
--
%

Flow
1.4
--
%

Water Absorption



ISO 62
Saturation, 73°F, 0.0787 in
6.1
--
%

Equilibrium, 73°F, 0.0787 in, 50% RH
1.9
--
%

Mechanical
Dry
Conditioned
Unit
Test Method
Tensile Modulus
754000
609000
psi
ISO 527-2/1A/1
Tensile Stress (Break)
13100
9430
psi
ISO 527-2/1A/5
Tensile Strain (Break)
8.0
12
%
ISO 527-2/1A/5
Flexural Modulus 3
653000
--
psi
ISO 178
Flexural Stress 3
19600
--
psi
ISO 178
Impact
Dry
Conditioned
Unit
Test Method
Charpy Notched Impact Strength



ISO 179/1eA
-22°F
1.9
--
ft·lb/in²

73°F
2.1
2.4
ft·lb/in²

Charpy Unnotched Impact Strength



ISO 179/1eU
-22°F
19
--
ft·lb/in²

73°F
26
33
ft·lb/in²

Thermal
Dry
Conditioned
Unit
Test Method
Heat Deflection Temperature




66 psi, Unannealed
419
--
°F
ISO 75-2/Bf
264 psi, Unannealed
194
--
°F
ISO 75-2/Af
Vicat Softening Temperature
473
--
°F
ISO 306/B50
Melting Temperature
500
--
°F
ISO 11357
Electrical
Dry
Conditioned
Unit
Test Method
Surface Resistivity
1.0E+12
1.0E+10
ohms
IEC 60093
Volume Resistivity
1.0E+15
1.0E+13
ohms·cm
IEC 60093
Comparative Tracking Index
500
--
V
IEC 60112
Flammability
Dry
Conditioned
Unit
Test Method
Burning Rate
0.0
--
in/min
FMVSS 302
Flame Rating (0.031 in)
HB
--

UL 94
Glow Wire Flammability Index (0.08 in)
1290
--
°F
IEC 60695-2-12
Injection
Dry
Unit

Drying Temperature - Desiccant Dryer
176
°F

Drying Time - Desiccant Dryer
2.0 to 4.0
hr

Dew Point - Desiccant Dryer
< -4
°F

Suggested Max Moisture
0.15
%

Processing (Melt) Temp
536 to 572
°F

Mold Temperature
176 to 212
°F

Injection Rate
Moderate-Fast




Products are widely used in plastic modification, automotive, construction, electrical and electronic, industrial, daily necessities and other fields


Consultation
展开