Products

Amilan® CM1011G-45

Amilan® CM1011G-45

Manufacturer:  TORAY
Produced At:
  Japan / China
Product Category:  PA6
Product No:  Amilan CM1011G-45
Product Quantity:  25KG / BAG
Product Features:  flame rated

Amilan® CM1011G-45

Polyamide 6
Product Description:
Amilan® CM1011G-45 is a Polyamide 6 (Nylon 6) product filled with 45% glass fiber. It is available in Asia Pacific, Europe, or North America. Typical application: Automotive. Primary characteristic: flame rated.

Filler / Reinforcement 
  • Glass Fiber, 45% Filler by Weight

Uses 
  • Automotive Applications

Part Marking Code 
  • >PA6-GF45<

Physical
Dry
Conditioned
Unit
Test Method
Density (73°F)
1.50
--
g/cm³
ISO 1183
Molding Shrinkage 3



Internal Method
Across Flow : 0.118 in
0.40 to 0.60
--
%

Flow : 0.118 in
0.10 to 0.30
--
%

Water Absorption



ISO 62
73°F, 24 hr
0.90
--
%

Saturation, 73°F
5.3
--
%

Hardness
Dry
Conditioned
Unit
Test Method
Rockwell Hardness



ISO 2039-2
M-Scale, 73°F
95
--


R-Scale, 176°F
30
--


R-Scale, 73°F
121
--


Mechanical
Dry
Conditioned
Unit
Test Method
Tensile Stress



ISO 527-2
-40°F
42100
36300
psi

73°F
29700
18900
psi

176°F
17400
12300
psi

Tensile Strain



ISO 527-2
Break, -40°F
3.0
3.0
%

Break, 73°F
3.0
3.0
%

Break, 176°F
5.0
5.0
%

Flexural Modulus



ISO 178
-40°F
2.34E+6
2.07E+6
psi

73°F
2.00E+6
1.17E+6
psi

176°F
1.03E+6
725000
psi

Flexural Stress



ISO 178
-40°F
55800
47100
psi

73°F
49300
30500
psi

176°F
26800
18100
psi

Compressive Stress



ISO 604
-40°F
37700
31900
psi

73°F
27600
17400
psi

176°F
14500
10200
psi

Shear Strength (73°F)
13800
10900
psi
ASTM D732
Taber Abrasion Resistance (1000 Cycles)
0.350
--
mg
ISO 9352
Coefficient of Friction - vs. Metal  4
0.15
--

Suzuki Method
Impact
Dry
Conditioned
Unit
Test Method
Charpy Notched Impact Strength



ISO 179
-40°F
7.1
8.1
ft·lb/in²

73°F
8.8
11
ft·lb/in²

Charpy Unnotched Impact Strength



ISO 179
-40°F
43
45
ft·lb/in²

73°F
48
57
ft·lb/in²

Thermal
Dry
Conditioned
Unit
Test Method
Heat Deflection Temperature (66 psi, Unannealed)
437
--
°F
ISO 75-2/B
Melting Temperature
437
--
°F
DSC
CLTE - Flow
1.1E-5 to 1.7E-5
--
in/in/°F
ISO 11359-2
Specific Heat
0.335
--
Btu/lb/°F

Thermal Conductivity
2.8
--
Btu·in/hr/ft²/°F

Electrical
Dry
Conditioned
Unit
Test Method
Volume Resistivity
1.0E+13
1.0E+10
ohms·cm
IEC 60093
Electric Strength
480
380
V/mil
IEC 60243-1
Dielectric Constant 5



IEC 60250
73°F, 50 Hz
5.00
9.50


73°F, 1 kHz
4.90
7.40


73°F, 1 MHz
4.20
4.50


Dissipation Factor 5



IEC 60250
73°F, 50 Hz
0.030
0.16


73°F, 1 kHz
0.030
0.15


73°F, 1 MHz
0.030
0.060


Arc Resistance 6
104
109
sec
UL 746
Flammability
Dry
Conditioned
Unit
Test Method
Flame Rating (0.06 in)
HB
HB

UL 94


Products are widely used in plastic modification, automotive, construction, electrical and electronic, industrial, daily necessities and other fields