Physical
Dry
Conditioned
Unit
Test Method
Density (73°F)
1.25
--
g/cm³
ISO 1183
Molding Shrinkage - Across Flow  3(0.118 in)
0.70 to 1.1
--
%
Internal Method
Water Absorption



ISO 62
73°F, 24 hr
1.3
--
%

Saturation, 73°F
8.3
--
%

Hardness
Dry
Conditioned
Unit
Test Method
Rockwell Hardness



ISO 2039-2
M-Scale, 73°F
90
--


R-Scale, 176°F
10
--


R-Scale, 73°F
119
--


Mechanical
Dry
Conditioned
Unit
Test Method
Tensile Stress



ISO 527-2
-40°F
19600
16700
psi

73°F
16000
7980
psi

176°F
6530
3630
psi

Tensile Strain



ISO 527-2
Break, -40°F
2.0
3.0
%

Break, 73°F
2.0
4.5
%

Break, 176°F
5.5
6.0
%

Flexural Modulus



ISO 178
-40°F
1.06E+6
870000
psi

73°F
827000
392000
psi

176°F
334000
247000
psi

Flexural Stress



ISO 178
-40°F
29700
--
psi

73°F
24700
12300
psi

176°F
11600
6530
psi

Compressive Stress



ISO 604
-40°F
29700
18900
psi

73°F
19600
9430
psi

176°F
10200
5080
psi

Shear Strength (73°F)
14500
--
psi
ASTM D732
Taber Abrasion Resistance (1000 Cycles)
0.300
--
mg
ISO 9352
Coefficient of Friction - vs. Metal  4
0.15
--

Suzuki Method
Impact
Dry
Conditioned
Unit
Test Method
Charpy Notched Impact Strength



ISO 179
-40°F
2.6
3.1
ft·lb/in²

73°F
4.0
3.3
ft·lb/in²

Charpy Unnotched Impact Strength



ISO 179
-40°F
9.5
12
ft·lb/in²

73°F
14
17
ft·lb/in²

Thermal
Dry
Conditioned
Unit
Test Method
Heat Deflection Temperature (66 psi, Unannealed)
410
--
°F
ISO 75-2/B
Melting Temperature
437
--
°F
DSC
CLTE - Flow
2.5E-5
--
in/in/°F
ISO 11359-2
Specific Heat
0.406
--
Btu/lb/°F

Thermal Conductivity
2.2
--
Btu·in/hr/ft²/°F

Electrical
Dry
Conditioned
Unit
Test Method
Volume Resistivity
1.0E+13
1.0E+10
ohms·cm
IEC 60093
Electric Strength
510
--
V/mil
IEC 60243-1
Dielectric Constant 5



IEC 60250
73°F, 50 Hz
4.50
--


73°F, 1 kHz
4.30
--


73°F, 1 MHz
3.70
--


Dissipation Factor 5



IEC 60250
73°F, 50 Hz
0.050
--


73°F, 1 kHz
0.040
--


73°F, 1 MHz
0.030
--


Arc Resistance 6
120
--
sec
UL 746
Flammability
Dry
Conditioned
Unit
Test Method
Flame Rating (0.06 in)
HB
HB

UL 94