Products

Makrolon® 2408

Makrolon® 2408

Manufacturer: Covestro
Produced At:
 Europe / China
Product Category: Polycarbonate
PC
Product No: Makrolon 2408 
Product Quantity: 25KG / BAG
Product Features: 
Biocompatible、Ethylene Oxide Sterilizable、Low Viscosity、Steam Sterilizable

Makrolon® 2408

Polycarbonate
Product Description:
MVR (300 °C/1.2 kg) 19 cm³/10 min; medical devices; suitable for ETO and steam sterilization at 121 °C; biocompatible according to many ISO 10993-1 test requirements; low viscosity; injection molding - melt temperature 280 - 320 °C; available in color code 000000 only

Features 
  • Biocompatible,Ethylene Oxide Sterilizable,Low Viscosity,Steam Sterilizable 
Uses 
  • Medical Devices,Medical/Healthcare Applications 
Agency Ratings 
  • ISO 10993-Part 1

RoHS Compliance 
  • RoHS Compliant

Processing Method 
  • Injection Molding

Physical
Nominal Value
Unit
Test Method
Density (73°F)
1.20
g/cm³
ISO 1183
Apparent (Bulk) Density 2
0.66
g/cm³
ISO 60
Melt Mass-Flow Rate (MFR) (300°C/1.2 kg)
20
g/10 min
ISO 1133
Melt Volume-Flow Rate (MVR) (300°C/1.2 kg)
1.16
in³/10min
ISO 1133
Molding Shrinkage



Across Flow
0.50 to 0.70
%
ISO 2577
Flow
0.50 to 0.70
%
ISO 2577
Across Flow : 0.0787 in 3
0.65
%
ISO 294-4
Flow : 0.0787 in 3
0.65
%
ISO 294-4
Water Absorption


ISO 62
Saturation, 73°F
0.30
%

Equilibrium, 73°F, 50% RH
0.12
%

Hardness
Nominal Value
Unit
Test Method
Ball Indentation Hardness
16400
psi
ISO 2039-1
Mechanical
Nominal Value
Unit
Test Method
Tensile Modulus (73°F)
341000
psi
ISO 527-2/1
Tensile Stress


ISO 527-2/50
Yield, 73°F
9430
psi

Break, 73°F
10200
psi

Tensile Strain


ISO 527-2/50
Yield, 73°F
6.3
%

Break, 73°F
120
%

Nominal Tensile Strain at Break (73°F)
> 50
%
ISO 527-2/50
Tensile Creep Modulus


ISO 899-1
1 hr
319000
psi

1000 hr
276000
psi

Flexural Modulus 4 (73°F)
341000
psi
ISO 178
Flexural Stress 4


ISO 178
73°F
13900
psi

3.5% Strain, 73°F
10400
psi

Flexural Strain at Flexural Strength 5 (73°F)
7.0
%
ISO 178
Impact
Nominal Value
Unit
Test Method
Charpy Notched Impact Strength 6


ISO 7391
-22°F, Complete Break
6.7
ft·lb/in²

73°F, Partial Break
31
ft·lb/in²

Charpy Unnotched Impact Strength


ISO 179/1eU
-76°F
No Break


-22°F
No Break


73°F
No Break


Notched Izod Impact Strength 7


ISO 7391
-22°F, Complete Break
7.1
ft·lb/in²

73°F, Partial Break
31
ft·lb/in²

Multi-Axial Instrumented Impact Energy


ISO 6603-2
-22°F
47.9
ft·lb

73°F
40.6
ft·lb

Multi-Axial Instrumented Impact Peak Force


ISO 6603-2
-22°F
1350
lbf

73°F
1150
lbf

Thermal
Nominal Value
Unit
Test Method
Heat Deflection Temperature



66 psi, Unannealed
282
°F
ISO 75-2/B
264 psi, Unannealed
261
°F
ISO 75-2/A
Glass Transition Temperature 8
297
°F
ISO 11357-2
Vicat Softening Temperature



--
297
°F
ISO 306/B50
--
298
°F
ISO 306/B120
Ball Pressure Test (280°F)
Pass

IEC 60695-10-2
CLTE


ISO 11359-2
Flow : 73 to 131°F
3.6E-5
in/in/°F

Transverse : 73 to 131°F
3.6E-5
in/in/°F

Thermal Conductivity 9 (73°F)
1.4
Btu·in/hr/ft²/°F
ISO 8302
Flammability
Nominal Value
Unit
Test Method
Flash Ignition Temperature
896
°F
ASTM D1929
Self Ignition Temperature
1022
°F
ASTM D1929
Optical
Nominal Value
Unit
Test Method
Refractive Index 10
1.586

ISO 489
Transmittance


ISO 13468-2
39.4 mil
89.0
%

78.7 mil
89.0
%

118 mil
88.0
%

157 mil
87.0
%

Haze (118 mil)
< 0.80
%
ISO 14782
Additional Information
Nominal Value


ISO Shortname
ISO 7391-PC,M,(,,)-18-9




Products are widely used in plastic modification, automotive, construction, electrical and electronic, industrial, daily necessities and other fields


Consultation
展开