Products

Ultraform® E3120 BM

Ultraform® E3120 BM

Manufacturer:  BASF
Produced At:
  Europe / China
Product Category:  Acetal (POM) Copolymer
Product No:  
Ultraform E3120 BM
Product Quantity:  25KG / BAG
Product Features: 
 CopolymerGood StretchabilityHigh Melt StrengthHigh Stiffness

Ultraform® E3120 BM

Acetal (POM) Copolymer
Product Description:
Material with high melt strength, -stiffness and high stretchability for producing extrusion blow-molded hollow objects.

Features 
  • Copolymer

  • Good Stretchability

  • High Melt Strength

  • High Stiffness 

Agency Ratings 
  • EC 1907/2006 (REACH)

RoHS Compliance 
  • RoHS Compliant

Forms 
  • Granules

Processing Method 
  • Extrusion Blow Molding

Resin ID (ISO 1043)
  • POM

Physical
Nominal Value
Unit
Test Method
Density
1.41
g/cm³
ISO 1183
Apparent (Bulk) Density
0.85
g/cm³

Melt Volume-Flow Rate (MVR) (190°C/2.16 kg)
0.0488
in³/10min
ISO 1133
Water Absorption


ISO 62
Saturation, 73°F
0.80
%

Equilibrium, 73°F, 50% RH
0.20
%

Hardness
Nominal Value
Unit
Test Method
Ball Indentation Hardness (H 358/30)
19600
psi
ISO 2039-1
Mechanical
Nominal Value
Unit
Test Method
Tensile Modulus
355000
psi
ISO 527-2
Tensile Stress (Yield)
9140
psi
ISO 527-2/50
Tensile Strain (Yield)
9.0
%
ISO 527-2/50
Nominal Tensile Strain at Break
25
%
ISO 527-2/50
Impact
Nominal Value
Unit
Test Method
Charpy Notched Impact Strength (73°F)
3.8
ft·lb/in²
ISO 179/1eA
Charpy Unnotched Impact Strength (73°F)
110
ft·lb/in²
ISO 179/1eU
Thermal
Nominal Value
Unit
Test Method
Heat Deflection Temperature (264 psi, Unannealed)
194
°F
ISO 75-2/A
Melting Temperature
327
°F
ISO 11357-3
CLTE - Flow (73 to 131°F)
6.7E-5
in/in/°F
ISO 11359-2
Maximum Service Temperature - short cycle operation
212
°F

Electrical
Nominal Value
Unit
Test Method
Surface Resistivity
1.0E+13
ohms
IEC 60093
Volume Resistivity
1.0E+15
ohms·cm
IEC 60093
Relative Permittivity (1 MHz)
3.80

IEC 60250
Dissipation Factor (1 MHz)
5.0E-3

IEC 60250
Comparative Tracking Index (Solution A)
600
V
IEC 60112
Flammability
Nominal Value
Unit
Test Method
Flame Rating (0.06 in)
HB

UL 94
Additional Information
Nominal Value

Test Method
ISO Type
POM-K, B-GNR, 01-002

ISO 9988-1


Products are widely used in plastic modification, automotive, construction, electrical and electronic, industrial, daily necessities and other fields


Consultation